説明
If It Is Not Measured, It Is Not Managed. Every electricity decision a business makes, whether to size a solar array, to bill a tenant, to find the machine that runs hot on the night shift, or to prove a saving to an investor, begins with the same missing number. Utility bills arrive monthly, aggregated, anonymous. They tell you what the building did, never what the process inside it did. A metering layer converts that silence into a ledger, and a ledger is the difference between an opinion about energy and a fact about it.
This is a DIN-rail meter family, not a single part. The DDSU666 covers single-phase loads up to 80A direct, the DTSU666 handles three-phase service with current-transformer inputs at 100A, 150A, 200A, 250A and 300A, and the DTSU666-H adds three CTs for three-phase circuits. The SDM230, SDM630MCT, YDS60-C24 and YDS70-C16 models in the same listing give you the form factors that fit existing panels. Every unit reports voltage, current, power and cumulative energy over MODBUS RS485, which is the one protocol a building management system, a Home Assistant instance, an EMQX broker and an industrial PLC all already speak. Wiring is terminal-block, the enclosure is alloy, and mounting is a standard rail clip.
Read the compatibility line before you buy. These meters are designed for general AC metering at 230V single phase and 380V three phase, and the listing is explicit that they are not validated for the inverter ecosystems of Solax, Sofar, Sungrow, Growatt, Huawei, Deye, Hoymiles or Goodwe. Panel builders, tenant sub-metering projects, hotel load audits and retrofits where the meter has to fit an already-crowded rail are the intended home for this hardware.
A number on a rail is worth more than a story about the bill.
Key Features
- ✦ DIN-rail mounting with terminal-block wiring, sized for standard distribution panels
- ✦ Direct 80A measurement in single phase, CT input from 100A to 300A in three phase
- ✦ MODBUS RS485 output, readable by BMS platforms, PLCs, brokers and open-source dashboards
- ✦ Measures voltage, current, active power and cumulative kWh energy
- ✦ Multi-model listing: DDSU666, DTSU666, DTSU666-H, DDSU666-H, SDM230, SDM630MCT, YDS60-C24 and YDS70-C16
- ✦ Supports 230V single-phase and 380V three-phase service configurations
- ✦ Alloy housing with the seal and stability expected in a panel installation
- ✦ Explicit compatibility notice published on the listing, so unsuitable inverter pairings are avoided before purchase
Technical Specifications
- Function: Digital voltmeter, ammeter, power and cumulative energy meter
- Mounting: DIN rail, terminal-block connections
- Protocol: MODBUS over RS485
- Single-Phase Model: DDSU666, 80A direct connection
- Three-Phase Models: DTSU666 and DTSU666-H with CT inputs, 100A, 150A, 200A, 250A and 300A
- Alternative Models: DDSU666-H, SDM230, SDM630MCT, YDS60-C24, YDS70-C16
- Voltage: AC 230V single phase, AC 380V three phase
- Measured Values: Voltage, current, power, energy
- Housing Material: Alloy
- Brand: CHINT / CHNT
- Not Validated With: Solax, Sofar, Sungrow, Growatt, Huawei, Deye, Hoymiles and Goodwe inverter ecosystems
- Price Range: Entry single-phase unit through to three-CT three-phase kits
Where It Belongs
This meter belongs in the parts of a building where energy becomes accountable. A landlord sub-metering commercial units needs a reading per tenant, not a reading per building. A fabrication shop wants to know which machine is the expensive one, so a rail meter goes in the feed to each bench. Hotels and laundries use them to separate house loads from kitchen loads. Solar installers use them behind the inverter to verify generation against consumption, except on the inverter brands the listing rules out. Facilities teams use them as the evidence layer for retrofit savings. If a process consumes power on a circuit, a DIN-rail meter on that circuit converts the wire into a data source.
Frequently Asked Questions
Q: Which model do I need for a three-phase supply?
Choose a DTSU666 or DTSU666-H variant and match the CT rating to your load. The 3CT models include three current transformers in the 100A, 150A, 200A, 250A and 300A ratings listed.
Q: How do I read the data into a dashboard or BMS?
The meter speaks MODBUS over RS485. Connect the A and B pair to your RS485 bus and poll the meter registers from a PLC, a BMS, a gateway, or an open-source energy dashboard.
Q: Will it work with my Growatt or Solax inverter?
No. The listing states clearly that these meters are not for Solax, Sofar, Sungrow, Growatt, Huawei, Deye, Hoymiles or Goodwe installations. Use the inverter manufacturer own metering for those systems.
Q: Is the 80A version direct-connected?
Yes. The DDSU666 80A variant measures the load directly without external current transformers, which keeps the panel wiring simple at that rating.
Q: What mounting space does it take?
It clips to a standard DIN rail and wires through terminal blocks, so it fits the same rail as the breakers and contactors already in the panel.
Q: What is in the box?
One meter, with current transformers included on the three-phase CT models as listed. CT leads and signal wiring are supplied as part of the metering kit.
The EastSupplier Promise
Every unit is inspected before it leaves the warehouse. If a specification on this page does not match what arrives, we cover the return shipping and replace it. English-language support answers within one business day, and replacement parts for this category are stocked so that a working unit stays working.









Customer Reviews
Payment and Security
お支払い情報は安全に処理されます。 クレジットカードの詳細を保存したり、クレジットカード情報にアクセスすることはありません