Hot runner temperature controller


Description

General Specifications

MBTC-10A
Hot Runner Temperature Controller Series

Power Supply 1-phase 3-wire, 240Vac, 50/60Hz

 

3-phase 4-wire, 240Vac, 50/60Hz

3-phase 5-wire, 380Vac, 50/60Hz

Mainframe Black
Control Module MBTC-A / MBTC-B / MBTC-C / MBTC-G
Sensor Type Thermocouple J or K Module Qt’y 10
Temperature Control 0~450℃(32~842℉) Control Mode Auto-PID / Manual
Output Type Zero Cross / Phase Angle Control Accuracy ±0.1%F.S
Connector Type Customized Load Capacity 15A, 3600W
Wiring Mode Customized Storage Temperature -20~70℃(-4~158℉)
Working Temperature 0~55℃(32~131℉) Working Humidity 10~80%RH(No condensing)

 

Features

Light Handy and Easy to use

Wide power supply range, AC85~400V
There are 2, 4, 6, 8, 10, 12, 24 zones for customers to select. • Thermocouple input protection, prevent module damaged by mis-connection • Thermocouple & heater inverse protection, prevent thermocouple damaged by mis-connection
Soft-start mode, avoid the humidity make the heater burn out
Compatible with YUDO, Athena, DME, PCS, INCOE,etc.

Alarm when the followings occurred
Ultra-high or ultra-low Temperature
2. Thermocouple break, short or inverse
3. Thermocouple is out of its position
4. Heater break, short or overload
5. Output device is damaged
Over voltage of power supply

Protection activated in the following situations:
Over voltage self-protectd, max.AC500V
Thermocouple input protection, prevent module damaged by misconnection
Thermocouple & heater inverse protection, prevent thermocouple damaged by misconnection
Soft-start mode, avoid the moisture make the heater burn out
5.Heater dehumidified time can be extended

PANEL INTRODUCTION

COMPONETS
■ Mainframe■ Module■ Connector■ Cable■ Blank plate (Exclude 2, 4, 6, 8,10,