説明
Every finished wall hides a decision. The Quiet Vault is the decision made correctly: an 86 x 86 mm concrete wiring cassette molded from flame-resistant, anti-corrosion PVC, built to sit inside poured concrete and take more than 100 kg of direct pressure without deforming. It is the least visible component in a room and the one that determines whether the wall is still sound in twenty years.
The detail that matters on site is the pair of movable nuts on each side. Standard boxes assume the electrician has room to work and the plate will line up. Concrete does not cooperate. Those sliding nuts allow a double, triple or mixed switch plate to be aligned after the pour, which is the difference between a flat plate and a wall that needs patching because a socket sits two millimeters proud.
Depth adjustment runs the same way. The cassette accepts the adjustable collar that lets the front edge meet the finished plaster instead of sitting behind it or standing off it. For anyone running EU or UK switchgear into concrete, block or a formwork pour, this is the part that makes the rest of the installation behave.
You will never see it. You will notice every time it is done wrong.
What Makes It Different
- ✦86 x 86 mm footprint matches standard EU and UK switch and socket modules, so generic plates fit without adapters.
- ✦Flame-resistant PVC formulation resists ignition and corrosion in damp concrete and block construction.
- ✦Rated to withstand over 100 kg of direct pressure, which is the load a poured wall actually applies.
- ✦Dual movable nuts on both sides allow the plate to be squared up after the concrete has set.
- ✦Adjustable collar brings the box face flush with finished plaster on uneven pours and deep chases.
- ✦Compact 86 x 86 mm body fits inside formwork without displacing the reinforcement around it.
- ✦Accepts single, double and triple plate configurations from the same cassette, which simplifies stocking.
Technical Specifications
- Dimensions86 x 86 mm, EU and UK standard
- MaterialFlame-resistant, anti-corrosion PVC
- Pressure ratingOver 100 kg direct load
- MountingConcrete and masonry, in-wall cassette
- AdjustmentDual movable nuts each side, adjustable depth collar
- CompatibilityEU and UK switch and socket modules
- Plate configurationsSingle, double and triple
- InstallationSet into formwork before the pour
- FinishMatte, paintable surfaces
- ApplicationResidential, commercial and industrial wiring
Where It Earns Its Place
This cassette is specified where the wall is the structure: poured concrete apartments, masonry villas, basement and garage fit-outs, and commercial partitions built from block. Electrical contractors working on multi-unit projects use it because one part covers single, double and triple plates, which cuts stocking complexity. It is also the right choice for retrofit work where a chase has been cut into an existing wall and the plate must be brought flush without breaking out more concrete than necessary.
The EastSupplier Promise
Sourced directly from vetted manufacturing partners, inspected before dispatch, and priced without distributor layers. If the item arrives outside specification, we replace it or refund it. Every listing on this store is curated by a human buyer, not bulk-imported and abandoned.
Questions Buyers Actually Ask
Q: Does this box work with UK square-edge plates?
The 86 x 86 mm footprint is the standard module used across EU and UK switchgear, so standard plates fit directly. If your plate uses a proprietary adapter frame, mount the adapter to the box first and check alignment before the pour.
Q: Can it be installed into an existing wall?
Yes, provided you cut a clean 86 x 86 mm chase that gives the box room to seat. With existing concrete, use the adjustable nuts to bring the face flush with the finished surface rather than chasing deeper.
Q: How does the 100 kg pressure rating apply?
It describes the load the cassette withstands from poured concrete and finished wall pressure without collapsing. It is a structural rating, not a load you hang from the box; fix heavy fixtures to the wall structure itself.
Q: Is the PVC suitable for damp basements?
The compound is anti-corrosion and does not absorb moisture the way metal boxes can. In permanently wet environments, still seal the cable entries with the appropriate grommets or sealant.
Q: Can I fit a triple plate to this box?
Yes. The dual movable nuts let the frame be adjusted to accept single, double and triple plates. Align all three module openings before tightening, since the nuts move independently.
Q: Do I need a separate depth collar?
Depth adjustment is handled by the movable mounting points and the collar geometry in the standard set. Check the wall thickness at the planning stage, because extreme thickness may need a deeper cassette.
Q: What cable entries does it accept?
Standard conduit and cable glands for 86 mm cassettes. Knock-outs can be opened with a knife or punch; seal unused entries so concrete slurry cannot enter during the pour.
Q: Will it fit inside standard formwork?
The 86 mm body is compact enough for typical wall formwork with 100 to 150 mm walls. Fix it to the formwork face so it cannot float when the concrete is vibrated.
Q: Is it paintable?
Yes. The matte surface takes plaster and paint. Tape the interior and the module openings before plastering so the threads and mounting points stay clean.








Customer Reviews
Payment and Security
お支払い情報は安全に処理されます。 クレジットカードの詳細を保存したり、クレジットカード情報にアクセスすることはありません
