The Cold Signal | A/C Pressure Switch for Audi A4 and A6

EastSupplier PlatformSKU:1005006136778288-Silver-China Mainland

Color: Silver
Prezzo:
$24.27

Tasse incluse spese di spedizione calcolata al pagamento

Disponibilità:
Disponibile

Descrizione

Air conditioning fails in a specific order. The compressor stops, the fan keeps running, and the cabin slowly turns into a greenhouse. The Cold Signal is the pressure switch that tells the compressor when to run, and it is the part a diagnostic scan points to once the refrigerant charge has been ruled out.

The switch reads refrigerant pressure on the high side and opens or closes the compressor circuit inside a defined band. When the diaphragm ages, that band drifts: the compressor short cycles, vent air turns cool rather than cold, and eventually the clutch stops engaging altogether. Replacing the sensor costs a fraction of a compressor, and it is the first thing a competent technician checks.

This unit cross references 3R0959126, 8E0959126, 8E0959126C, 8E0959126A, and SW11313C, which covers a spread of Audi A4 and A6 platforms along with Volkswagen applications sharing the same HVAC architecture. The housing is sealed against refrigerant oil and engine bay heat, and the connector is keyed so it seats one way and locks.

Cold air is a chain of small decisions. This is the link that most often breaks.


Key Features

  • ✦  Replaces the high side pressure switch on the compressor circuit
  • ✦  Cross references 3R0959126, 8E0959126, 8E0959126C, and 8E0959126A
  • ✦  Also cataloged as SW11313C by aftermarket suppliers
  • ✦  Sealed housing resists refrigerant oil and engine bay heat
  • ✦  Keyed connector seats one way and locks
  • ✦  Restores the compressor cycle band a drifting sensor loses
  • ✦  Fits Audi A4 and A6 platforms sharing the same HVAC layout

Technical Specifications

  • Part type: air conditioning pressure switch
  • OEM references: 3R0959126, 8E0959126, 8E0959126C, 8E0959126A
  • Aftermarket reference: SW11313C
  • Function: compressor circuit control by refrigerant pressure
  • Housing: sealed
  • Connector: keyed and locking
  • Fitment: Audi A4, Audi A6, selected Volkswagen models
  • Finish: silver body with black connector
  • Installation: threaded port, no modification
  • Quantity: one switch

Where It Earns Its Place

Independent shops fit it when a customer reports weak cooling with a full charge. Owners doing their own diagnosis reach for it after ruling out the cabin filter and the blower. Fleet maintenance keeps one on the shelf, because a failed switch takes a vehicle out of summer service as surely as a failed compressor.

The EastSupplier Promise

Sourced from vetted manufacturing partners, inspected before dispatch, and priced without distributor layers. If the item arrives outside specification, we replace it or refund it. Every listing here is curated by a human buyer.

Questions Buyers Ask Before Ordering

Q: Will this fix my air conditioning?

A: Only if the switch is the actual fault. Confirm the system holds pressure and that the compressor is not being commanded for another reason before replacing parts.

Q: Do I need to evacuate the system?

A: Yes. The switch sits on a pressurized port, so the refrigerant must be recovered before it is removed and the system recharged afterwards.

Q: Which vehicles does it fit?

A: Audi A4 and A6 platforms plus selected Volkswagen models that use the same HVAC layout. Match the OEM number on the part you are removing.

Q: How do I confirm fitment?

A: Compare the OEM number stamped on the old switch with the references listed here. That is more reliable than matching model years alone.

Q: Does it come with the connector?

A: The switch only. It reuses the existing harness connector, which unclips from the old part.

Q: Is this a genuine OEM part?

A: It is an aftermarket switch built to the listed OEM references. If you need a dealer-boxed part, check with us before ordering.

Q: What are the symptoms of a failed switch?

A: Short compressor cycling, weak cooling with a correct charge, or no clutch engagement at all. A scan tool usually flags the pressure circuit.

Q: Will it need coding or programming?

A: No. It is a pressure switch rather than a module, so it works once connected.

Q: Should I use thread sealant?

A: No. The seal is an O-ring on the port. Tape or paste can block the port and give a false reading.

Q: How long does the job take?

A: Roughly twenty to thirty minutes with recovery and recharge equipment, longer if access to the port is tight.

Q: Can I swap it without recovering the refrigerant?

A: No. Recover the charge first, or the system vents to atmosphere and the job becomes more expensive than the part.

Q: Is this the same as a trinary switch?

A: No. This is a pressure switch on the compressor circuit. If your vehicle uses a trinary switch with three functions, compare the OEM number before ordering.

Q: Will the fault code clear after fitting?

A: The circuit returns once the switch reads correctly. Stored codes may still need clearing from the scan tool.

Customer Reviews

Customer Reviews

Based on 3 reviews
67%
(2)
33%
(1)
0%
(0)
0%
(0)
0%
(0)
M
Malcolm R.
Correct part, plan the recharge

Works as intended. Remember you need to recover and recharge the system, so budget for that too.

S
Sylvester B.
Matched the OEM number

Identical to the part I removed and the references lined up. My shop fitted it in half an hour with a recovery machine.

A
Atticus Z.
Fixed the short cycling

The charge was correct but the compressor kept cycling. Swapped this switch and the vent air went cold again. Connector seated with a click.

Payment and Security

PayPal

Le tue informazioni di pagamento vengono elaborate in modo sicuro. Non memorizziamo i dettagli della carta di credito né abbiamo accesso alle informazioni della tua carta di credito.

Previsione di spedizione

You may also like

Recently Seen