12V 24V NC NO Diesel Generator Engine Flame Out Device Off Valve Stop Solenoid Valve Normal Close Normal Open Generator Parts

Economisez 20%
East Supplier PlatformSKU: 1005005296031301-NO-Power On Pull-CHINA-24V

Color: NO-Power On Pull
Prix:
$14.50 $18.13
Stock:
113 en stock, prêts à être livrés

Description

SPECIFICATIONS

Brand Name: SHALUO

Origin: Mainland China

Model Number: XHQ-PT

is_customized: Yes

key name: Engine Stop Solenoid Valve

optional voltage: 12V/24V

normal close NC: when power off ,it will pull

normal open NO: When power on, it will pull

travel length: 52mm

wire diameter: 10mm

Normal Open 12V 24V Engine Flame Out Device Off Valve XHQ-PT- NO 

One: technical parameter

The purpose of working voltage: 12V (9-15V DC) 24V (18-30V DC)

Purpose: 12V-2.0A 24V-1.0A (full of action current moves in place automatically disconnect the power supply, the working current of <15mA)

In the line of control working current: <15mA

Travel: 53 + 1mm.

The maximum tension: 90N.

An ambient temperature: -30 to 60 DEG C

The action time: less than 2 seconds.

An overload protection extinguisher: the load is too large or stuck, stop working automatically,avoid flameout device damage. Disconnect the power off after a period of time, re power,extinguisher from fault reset, can resume normal work.

Two, flameout device wiring:

The flameout device has 3 lead wires, as follows:

Red: connect the positive power supply: the cathode of a power supply (yellow green or blue)as the line of control:

Open type: control line power extinguisher action, action in place, automatic stop. The release of extinguisher power, action in place, automatic stop.

Closed type: control line power extinguisher action, action in place, automatic stop.Release extinguisher power control line, automatic stop action in place.

Three, installation and notice

The installation and commissioning should ensure the extinguisher action in place before,diesel engine stop control rod no action to the limit position and the extinguisher stuck,otherwise the extinguisher internal overload protection circuit, automatic flameout device stops working, the extinguisher should disconnect the power, adjust the mounting position, back to the extinguisher on electricity, flameout which can resume normal work.