{"product_id":"the-cryocore-180w-refrigerant-vacuum-pump","title":"The CryoCore | 180W Industrial Refrigerant Vacuum Pump","description":"\u003cdiv class=\"product-narrative\"\u003e\n  \u003cp\u003ePressure is not a problem to be endured. It is a resource to be engineered.\u003c\/p\u003e\n  \u003cp\u003eThe CryoCore represents a fundamental rethinking of what a vacuum pump should be in the modern HVAC\/R workshop. Where commodity pumps treat evacuation as a waiting game — spin the motor, watch the gauge, hope the microns drop — this instrument treats it as a precision thermodynamic operation. The 180W single-stage rotary vane architecture is machined to tolerances that would be recognizable to a Swiss watchmaker: cylinder bore concentricity within 8 microns, rotor-to-stator clearance optimized for maximum volumetric efficiency without sacrificing ultimate vacuum depth. The result is a pump that pulls a 5 Pa ultimate vacuum — deep enough to boil moisture at ambient temperature, the true test of refrigeration-grade evacuation.\u003c\/p\u003e\n  \u003cp\u003eWhat separates a professional vacuum pump from a hobbyist unit is not the motor wattage printed on the label. It is the oil management system. The CryoCore employs a forced-feed lubrication circuit with an oversized oil reservoir that operates as both lubricant and thermal sink — the oil carries heat away from the compression chamber while simultaneously sealing the microscopic gap between rotor and stator. The gas ballast valve, often treated as an afterthought on budget pumps, is engineered here as a primary feature: open it during initial pull-down to purge moisture-laden vapor before it can emulsify with the oil, then close it for the deep-vacuum finish. This is the workflow that separates a system that holds vacuum for years from one that leaks refrigerant within months.\u003c\/p\u003e\n  \u003cp\u003e\u003cem\u003eEvacuation is not a step in a procedure. It is the foundation upon which every refrigeration system stands or falls.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003chr style=\"margin: 20px 0; border: 0; border-top: 1px solid #eee;\"\u003e\n\u003cdiv class=\"product-features\"\u003e\n  \u003ch3\u003eKey Features\u003c\/h3\u003e\n  \u003cul style=\"list-style: none; padding: 0;\"\u003e\n    \u003cli style=\"padding: 8px 0; border-bottom: 1px solid #eee;\"\u003e✦ 180W high-torque induction motor with thermal overload protection — sustained operation without duty-cycle anxiety\u003c\/li\u003e\n    \u003cli style=\"padding: 8px 0; border-bottom: 1px solid #eee;\"\u003e✦ 5 Pa (0.05 mbar) ultimate vacuum — surpasses the 15 Pa threshold required for R-410A and R-32 systems\u003c\/li\u003e\n    \u003cli style=\"padding: 8px 0; border-bottom: 1px solid #eee;\"\u003e✦ Forced-feed oil lubrication with anti-suck-back valve — prevents oil migration during power interruption\u003c\/li\u003e\n    \u003cli style=\"padding: 8px 0; border-bottom: 1px solid #eee;\"\u003e✦ Integrated gas ballast with graduated control — stage moisture purge before deep-vacuum hold\u003c\/li\u003e\n    \u003cli style=\"padding: 8px 0; border-bottom: 1px solid #eee;\"\u003e✦ Standard 1\/4\" and 3\/8\" SAE flare service ports with brass construction — chemical compatibility across R-22, R-134a, R-410A, R-32\u003c\/li\u003e\n    \u003cli style=\"padding: 8px 0; border-bottom: 1px solid #eee;\"\u003e✦ Die-cast aluminum housing with vibration-dampening rubber feet — workshop durability meets transport portability\u003c\/li\u003e\n    \u003cli style=\"padding: 8px 0; border-bottom: 1px solid #eee;\"\u003e✦ Sight glass oil level indicator — no guesswork, no overfilling, no starvation\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-specs\"\u003e\n  \u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n  \u003cul style=\"list-style: none; padding: 0;\"\u003e\n    \u003cli style=\"padding: 8px 0; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003ePower:\u003c\/strong\u003e 180W \/ 220V 50Hz \/ 1 Phase\u003c\/li\u003e\n    \u003cli style=\"padding: 8px 0; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eUltimate Vacuum:\u003c\/strong\u003e 5 Pa (0.05 mbar)\u003c\/li\u003e\n    \u003cli style=\"padding: 8px 0; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003ePumping Speed:\u003c\/strong\u003e 1.8 CFM (3.0 m3\/h)\u003c\/li\u003e\n    \u003cli style=\"padding: 8px 0; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eOil Capacity:\u003c\/strong\u003e 250 ml\u003c\/li\u003e\n    \u003cli style=\"padding: 8px 0; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eMotor Speed:\u003c\/strong\u003e 1440 RPM\u003c\/li\u003e\n    \u003cli style=\"padding: 8px 0; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eStage:\u003c\/strong\u003e Single-stage rotary vane\u003c\/li\u003e\n    \u003cli style=\"padding: 8px 0; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eIntake Port:\u003c\/strong\u003e 1\/4\" \u0026amp; 3\/8\" SAE flare\u003c\/li\u003e\n    \u003cli style=\"padding: 8px 0; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eHousing:\u003c\/strong\u003e Die-cast aluminum\u003c\/li\u003e\n    \u003cli style=\"padding: 8px 0; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eCompatibility:\u003c\/strong\u003e R-12, R-22, R-134a, R-410A, R-32, R-404A\u003c\/li\u003e\n    \u003cli style=\"padding: 8px 0; border-bottom: 1px solid #eee;\"\u003e\n\u003cstrong\u003eCertification:\u003c\/strong\u003e CE, RoHS\u003c\/li\u003e\n  \u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-applications\"\u003e\n  \u003ch3\u003eApplication Scenarios\u003c\/h3\u003e\n  \u003cp\u003eThe CryoCore is purpose-built for HVAC\/R professionals who service residential and light commercial split systems, mini-split heat pumps, walk-in coolers, and automotive air conditioning. It is the daily driver for technicians who evacuate 2-5 systems per day — scenarios where pump reliability directly determines job profitability. In refrigeration research and teaching laboratories, the 5 Pa ultimate vacuum provides sufficient depth for demonstrating thermodynamic principles. For appliance repair shops handling refrigerators, dehumidifiers, and ice machines, the compact form factor and integrated carry handle make it the natural choice over bulkier 3-4 CFM units that offer speed without precision.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-faq\"\u003e\n  \u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n  \u003cdiv style=\"margin-bottom: 15px;\"\u003e\n    \u003cp\u003e\u003cstrong\u003eQ: What oil should I use with this vacuum pump?\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cp\u003eA: Use ISO VG 68 or VG 100 vacuum pump oil specifically formulated for rotary vane pumps. Standard compressor oil lacks the low vapor pressure required for deep vacuum work — it will outgas and limit your ultimate vacuum depth. Change oil after every major evacuation or when it appears milky (indicating moisture contamination).\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"margin-bottom: 15px;\"\u003e\n    \u003cp\u003e\u003cstrong\u003eQ: Can this pump handle R-410A systems with POE oil?\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cp\u003eA: Yes. The 5 Pa ultimate vacuum is well below the 500-micron (67 Pa) threshold required for POE oil systems. R-410A is hygroscopic — its POE lubricant absorbs moisture rapidly. The CryoCore gas ballast valve allows you to purge moisture during initial pull-down, protecting both the pump oil and the system from contamination.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"margin-bottom: 15px;\"\u003e\n    \u003cp\u003e\u003cstrong\u003eQ: How does this compare to a two-stage pump?\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cp\u003eA: A two-stage pump can achieve deeper ultimate vacuum (typically 0.3-1 Pa), but the practical difference for HVAC field service is negligible. The CryoCore 5 Pa rating is deep enough to boil water at 0C — the gold standard for field evacuation. The single-stage design means fewer moving parts, lower maintenance, and lighter weight — advantages that matter every day on the job.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"margin-bottom: 15px;\"\u003e\n    \u003cp\u003e\u003cstrong\u003eQ: How long does evacuation take for a typical 3-ton split system?\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cp\u003eA: With proper hoses (3\/8\" or larger ID, no manifold restriction), expect 20-35 minutes to reach sub-500 micron levels on a clean, dry system. Systems with known moisture contamination benefit from triple evacuation: pull to 1000 microns, break vacuum with nitrogen, pull to 500, break again, final pull to below 500. The gas ballast should be open during the first two pulls.\u003c\/p\u003e\n  \u003c\/div\u003e\n  \u003cdiv style=\"margin-bottom: 15px;\"\u003e\n    \u003cp\u003e\u003cstrong\u003eQ: Is this pump suitable for continuous operation?\u003c\/strong\u003e\u003c\/p\u003e\n    \u003cp\u003eA: The thermal overload protection allows for extended runs, but rotary vane pumps are not designed for 24\/7 continuous operation like scroll or diaphragm pumps. For typical HVAC service (2-5 evacuations per day, 20-40 minutes each), the CryoCore operates well within its design envelope. Always allow the pump to cool between jobs.\u003c\/p\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"product-gallery\" style=\"margin-top: 30px; text-align: center;\"\u003e\n  \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0503\/6412\/1244\/files\/Hee4cc24e6d664a3aab741990184a0607J_9e55ba62-7a59-4c5c-b94d-28c3380d05d8.webp?v=1783477980\" alt=\"The CryoCore Vacuum Pump\" style=\"max-width: 100%; margin: 10px 0;\"\u003e\n  \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0503\/6412\/1244\/files\/H0bb0f5e7e1fd48bdab1c00848b960cc5J_28272137-3fbc-4100-ba09-08290d5e112c.webp?v=1783477980\" alt=\"The CryoCore Vacuum Pump\" style=\"max-width: 100%; margin: 10px 0;\"\u003e\n  \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0503\/6412\/1244\/files\/He2d5972fd1ea47ef89464d63755a3275T_a435d1dd-d693-4534-813d-cea8e38a3924.webp?v=1783477980\" alt=\"The CryoCore Vacuum Pump\" style=\"max-width: 100%; margin: 10px 0;\"\u003e\n  \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0503\/6412\/1244\/files\/H97aa159cc29d424f9e8ba1bcd95249f4h_455359a5-7d4b-4575-bf2e-ca5591710ae2.webp?v=1783477981\" alt=\"The CryoCore Vacuum Pump\" style=\"max-width: 100%; margin: 10px 0;\"\u003e\n  \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0503\/6412\/1244\/files\/Sba175671d40b4efab14e5c33e0b971c17_c0197b0d-d9b3-4f07-9794-ccb293e57c53.webp?v=1783477980\" alt=\"The CryoCore Vacuum Pump\" style=\"max-width: 100%; margin: 10px 0;\"\u003e\n\u003c\/div\u003e\u003cscript type=\"application\/ld+json\"\u003e\n{\n  \"@context\": \"https:\/\/schema.org\",\n  \"@type\": \"Product\",\n  \"name\": \"The CryoCore | 180W Industrial Refrigerant Vacuum Pump\",\n  \"description\": \"Industrial-grade 180W single-stage rotary vane vacuum pump for HVAC\/R evacuation, capable of pulling 5 Pa ultimate vacuum. Precision-machined components and oil-sealed design for professional refrigerant service.\",\n  \"sku\": \"CRYO-180V\",\n  \"brand\": {\"@type\": \"Brand\", \"name\": \"V-i120SV\"},\n  \"offers\": {\n    \"@type\": \"Offer\",\n    \"price\": \"679.63\",\n    \"priceCurrency\": \"USD\",\n    \"availability\": \"https:\/\/schema.org\/InStock\",\n    \"url\": \"https:\/\/eastsupplier.com\/products\/the-cryocore-180w-refrigerant-vacuum-pump\"\n  }\n}\n\u003c\/script\u003e","brand":"EastSupplier Platform","offers":[{"title":"220V \/ EU \/ China Mainland","offer_id":50538044981471,"sku":"32869736564-220V-EU-China Mainland","price":679.63,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0503\/6412\/1244\/files\/Hee4cc24e6d664a3aab741990184a0607J_9e55ba62-7a59-4c5c-b94d-28c3380d05d8.webp?v=1783477980","url":"https:\/\/eastsupplier.com\/fr-it\/products\/the-cryocore-180w-refrigerant-vacuum-pump","provider":"EastSupplier Platform","version":"1.0","type":"link"}