DP Type Split Core Current Transformer

Heyi

Description

Introduce:

DP type of split core current transformers have been designed to easily fit around cables without breaking the circuit.Its advantages of big capacity and big mounting hole size,could be used in more power applications.DP was global used in most power applications.

Features:

Double-screw fastening, safe, easy to install, portable.
Two built in fixing methods:Base;Busbar mounting
Wide inner window, allowing clamping of big cables or bus-bars.
Wide range of sizes to accommodate all the existing installations.
Primary current from 5A to 5000A.

Applications:

Current measurement, monitoring and piotection for electrical wiring and equipment.
Current and power measurement for electric motors, lighting, air compressor, heating and ventilation system,air-condition equipment and automation-control system.
Current, power and energy monitoring device.
Relay protection device.

Tecnial data

Electrical Parameter Mechanical Parameter
Frequency 50-400Hz Case PC/UL94-V0
Rated Input 5A-5000A Bobbin PBT
Measuring range 10%In-120%In Core Silicon steel
Rated Output 0-5A Internal structure Epoxy
Ratio ≤ ± 0.5% Construction Tie
Phase angle ≤ ±30min Operation Temp -25oC~+75oC
Dielectric strangth 2.5KV/1mA/1min Operating Humidity ≤85%
Insulation Resistance DC500V/100MΩ min Output Connection Terminal
MODEL Ratio Burden(VA)Accuracy Frequency(Hz)
0.5 1
DP-23 100/5A / 2.5VA 50/60Hz
150/5A / 2.5VA 50/60Hz
200/5A 2.5VA 5VA 50/60Hz
250/5A 2.5VA 5VA 50/60Hz
300/5A 5VA 5VA 50/60Hz
400/5A 5VA 5VA 50/60Hz
MODEL Ratio Burden(VA)Accuracy Frequency(Hz)
class:0.5 class:1
DP-58 250/5A / 2.5VA 50/60Hz
300/5A / 2.5VA 50/60Hz
400/5A 2.5VA 2.5VA 50/60Hz
500/5A 2.5VA 5VA 50/60Hz
600/5A 2.5VA 5VA 50/60Hz
800/5A 5VA 5VA 50/60Hz
1000/5A 5VA 10VA 50/60Hz
MODEL Ratio Burden(VA)Accuracy Frequency(Hz)
0.5 1
DP-88 250/5A / 2.5VA 50/60Hz
300/5A / 2.5VA 50/60Hz
400/5A 2.5VA 2.5VA 50/60Hz
500/5A 2.5VA 5VA 50/60Hz
600/5A 2.5VA 5VA 50/60Hz
800/5A 5VA 5VA 50/60Hz
1000/5A 5VA 10VA 50/60Hz
MODEL Ratio Burden(VA)Accuracy Frequency(Hz)
0.5 1
DP-812 500/5A / 2.5VA 50/60Hz
600/5A / 2.5VA 50/60Hz
750/5A 2.5VA 5VA 50/60Hz
800/5A 2.5VA 5VA 50/60Hz
1000/5A 5VA 10VA 50/60Hz
1200/5A 5VA 10VA 50/60Hz
1500/5A 5VA 10VA 50/60Hz
1600/5A 5VA 10VA 50/60Hz
2000/5A 5VA 10VA 50/60Hz
MODEL Ratio Burden(VA)Accuracy Frequency(Hz)
class:0.5 class:1
DP-816 1000/5A 5VA 10VA 50/60Hz
1200/5A 7.5VA 10VA 50/60Hz
1500/5A 7.5VA 10VA 50/60Hz
1600/5A 10VA 10VA 50/60Hz
2000/5A 10VA 15VA 50/60Hz
2500/5A 10VA 20VA 50/60Hz
3000/5A 20VA 25VA 50/60Hz
4000/5A 20VA 25VA 50/60Hz
5000/5A 20VA 25VA 50/60Hz